TRANSMIG 350i, 450i, 550i

INSTALLATION, OPERATION AND SETUP 3-14 Manual 0-5205

22. Control Circuit Breakers

22

A-10638

Figure 3-3: Circuit Breakers

These Circuit Breakers protects the unit from electrical faults.

The SOLENOID 4A and MOTOR 5A circuit breakers are for Wirefeeders connected to the 10 pin control

socket. The 42VAC 8A and 110VAC 4A circuit breakers are for Wirefeeders connected to the 19 pin control

socket. The Fan 3A circuit breaker protects the fan circuit in the event of a fault.

NOTE

If a circuit breaker trips, a short cooling period must be allowed before an attempt is made to reset

the unit by pressing the circuit breaker reset button. In the event that the circuit breaker will not

reset have an Accredited Cigweld Service provider investigate the fault.

23. Restore Factory Default Settings

The Transmig 350i, 450i and 550i can have Factory Default Settings Restored .This function is accessed

by pressing the AMPS and INDUCTANCE knobs at the same time for two seconds (2s). The VOLTS and

AMPS led's will flash 3 times to indicate a Factory Reset has been completed.

A-10973

Figure 3-4: Restore Factory Default Settings