Tweco 550i Transmig User Manual

Page 30

Advertising
background image

TRANSMIG 350i, 450i, 550i

INSTALLATION, OPERATION AND SETUP 3-10 Manual 0-5205

15. Advanced Features

The TRANSMIG 350i, 450i and 550i have a series of Advanced features that allow the control of multiple

parameters.

These are accessed by pressing the AMPS and VOLTS knobs at the same time.

Once in the Advanced Features mode, turn the AMP control to select the Parameter, and turn the VOLTS

control to adjust the value.

A-10633

Figure 3-2: Advanced Features

Program Number

Description

Amps

A-10634

Volts

A-10635

P01

SPOT TIME, adjustable from 0.5 to 5.0 seconds

P02

BURN BACK TIME, adjustable from 0.01 to 2.00 seconds

P03

PRE FLOW TIME, adjustable from 0.01 to 9.99 seconds

P04

POST FLOW TIME, adjustable from 0.01 to 9.99 seconds

P05

MMAW (Stick) HOT START CURRENT, adjustable from 10 to 100A

P06

CREEP FEED SPEED, adjustable from 0.05 to 20 MPM

P07

Wirefeed speed units, change between IPM and MPM

P08

Displays Software revision

Table 3-1: Advanced Features