Tweco 550i Transmig User Manual

Page 37

Advertising
background image

TRANSMIG 350i, 450i, 550i

Manual 0-5205 3-17

INSTALLATION, OPERATION AND SETUP

2. To reduce flow rate, allow the welding grade shielding gas to discharge from regulator by opening the

downstream valve. Bleed welding grade shielding gas into a well ventilated area and away from any

ignition source. Turn adjusting screw counterclockwise, until the required flow rate is indicated on the

gauge. Close downstream valve.

Shutdown

Close cylinder valve whenever the regulator is not in use. To shut down for extended periods (more than 30

minutes).

1. Close cylinder or upstream valve tightly.
2. Open downstream equipment valves to drain the lines. Bleed gas into a well ventilated area and away

from any ignition source.

3. After gas is drained completely, disengage adjusting screw and close downstream equipment valves.
4. Before transporting cylinders that are not secured on a cart designed for such purposes, remove

regulators.

3.08 Setup for MIG (GMAW) Welding with Gas Shielded Mig Wire

POWER SOURCE CONNECTIONS
A. Remove all packaging materials. Do not block the air vents at the front or rear of the Power Source.
B. Connect the work lead to the negative welding terminal (-) [positive welding terminal(+) for flux cored

electrode wire]. If in doubt, consult the electrode wire manufacturer. Welding current flows from the Power

Source via heavy duty bayonet type terminals. It is essential, however, that the male plug is inserted and

turned securely to achieve a sound electrical connection.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused

in the terminal.

!

WARNING

Before connecting the work clamp to the work piece make sure the mains power supply is switched

off.
Secure the welding grade shielding gas cylinder in an upright position by chaining it to a suitable

stationary support to prevent falling or tipping.

C. Position a gas cylinder on the rear tray of the Power Source and lock securely to the Power Source cylinder

bracket with the chain provided. If this arrangement is not used or the Power Source is not fitted with a

gas cylinder tray then ensure that the gas cylinder is secured to a building pillar, wall bracket or otherwise

securely fixed in an upright position.

D. Select MIG mode with the process selection control button.
WIREFEEDER CONNECTIONS
A. Connect the welding power cable from the Wirefeeder's interconnection cables to the positive welding

terminal (+) [negative welding terminal (-) for flux cored electrode wire]. If in doubt, consult the electrode

wire manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals.

It is essential, however, that the male plug is inserted and turned securely to achieve a sound electrical

connection.

B. Connect the control cable from the Wirefeeder to the 10 PIN or 19 PIN socket on the Power Source as

applicable.

Advertising