TRANSMIG 350i, 450i, 550i

Manual 0-5205

5-3 POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS

Note that due to the dangers of stray output currents damaging fixed wiring, the integrity of fixed wiring

supplying Cigweld welding power sources should be inspected by a licensed electrical worker in accordance

with the requirements below -

1. For outlets/wiring and associated accessories supplying transportable equipment - at least once

every 3 months; and

2. For outlets/wiring and associated accessories supplying fixed equipment - at least once every 12

months.

D. Voltage Reduction Device (VRD)

Units fitted with VRD's, shall have the periodic tests outlined in Table 6-2 below conducted by an accredited

CIGWELD service provider. Testing shall be conducted at intervals as outlined below -

1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.

Description

Required Parameters

VRD Open Circuit Voltage Less than 35V; at nominal input voltage
VRD Turn OFF Resistance

Less than 200 ohms

VRD Turn ON Time

Less than 0.3 seconds

Table 5-3: VRD Periodic Tests

E. General Maintenance Checks

Welding equipment should be regularly checked by an accredited Cigweld Service Provider to ensure that:

1. Flexible cord is of the multi-core tough rubber or plastic sheathed type of adequate rating, correctly

connected and in good condition.

2. Welding terminals are in suitable condition and are shrouded to prevent inadvertent contact or short

circuit.

3. The Welding System is clean internally, especially from metal filing, slag, and loose material.

F. Accessories

Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be

inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable

condition. All unsafe accessories shall not be used.

G. Repairs

If any parts are damaged for any reason, it is recommended that replacement be performed by an ac-

credited Cigweld Service Provider.

Power Source Calibration

A. Schedule

Output testing of all Cigweld Inverter Power Sources and applicable accessories shall be conducted at

regular intervals to ensure they fall within specified levels. Calibration intervals shall be as outlined below -

1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.

If equipment is to be used in a hazardous location or environments with a high risk of electrocution as

outlined in AS 1674.2 - 2007, then the above tests should be carried out prior to entering this location.