Tweco 550i Transmig User Manual

Page 33

Advertising
background image

TRANSMIG 350i, 450i, 550i

Manual 0-5205 3-13

INSTALLATION, OPERATION AND SETUP

21. 19 Pin Wirefeeder Control Socket

The WIREFEEDER 19 pin receptacle is used to connect a Wirefeeder to the welding Power Source circuitry.

To make connections, align keyway, insert plug, and rotate threaded collar fully clockwise. The socket

information is included in the event the supplied cable is not suitable and it is necessary to wire a plug or

cable to interface with the WIREFEEDER 19 pin receptacle.

A

B

C

D

E F G

H

K

J

L

M

R

P

N

S

T

U

V

A-10637

Socket Pin

Part Number / Description

A

Contactor + (Contact closure is provided between socket

pins A and B to energise the contactor)

B

Contactor - (Contact closure is provided between socket

pins A and B to energise the contactor)

C

Voltage feedback (1V=10V output voltage)

D

Not used

E

Input Supply 110VAC 4A with respect to Socket F (circuit common)

F

42VAC and 110VAC common

G

Chassis Ground (Mains Earth)

H

Remote Voltage Control Potentiometers Maximum

J

Remote Voltage Control Potentiometer Wiper

K

Remote Voltage Control Potentiometers Minimum

L

Control circuit common

M

Arc Established = +15V DC

N

Power Source Select Line (0V = wirefeeder enabled)

P

Not used

R

Not used

S

Input Supply 42VAC 8A with respect to Socket F (circuit common)

T

Not used

U

Current feedback (1V=100A output current)

V

Not used

Table 3-3: 19 Pin Interconnection Control Plug configuration

!

WARNING

The Protective Earth Ground pin G of the control cable is established only when the power source

is properly grounded