Technical Specifications

13

Overview of Cisco 3800 Series Routers

OL-5966-01

AC input power

Input voltage

Frequency

Input current

Inrush surge current

100–240 VAC, autoranging

47–63 Hz

3 A (8 A for IP phone support) at 110 V
2 A (4 A for IP phone support) at 230 V

50 A maximum, one cycle
(–48V IP phone power included)

DC input power

Input voltage

Input current

Inrush surge current

24–60 VDC, positive or negative, autoranging

12 A at 24 V; 5 A at 60 V

50 A maximum, <10 ms

Power dissipation
(maximum)

AC without
IP phone support

AC with
IP phone support:

System only

IP phones

DC

300 W (1025 BTU/hr)

370 W (1260 BTU/hr)

360 W (1230 BTU/hr)

325 W (1110 BTU/hr)

Console and auxiliary ports

RJ-45 connector

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

–40 to 185°F (–40 to 85°C)

Operating humidity

5–95%, noncondensing

Operating altitude

Up to 6,500 ft (2,000 m); derate temperature 1°C per
1,000 ft

Noise level

50 dBA typical, 53 dBA maximum

Regulatory compliance

FCC Part 15 Class A. For additional compliance
information, see the Cisco 2800 Series and Cisco 3800
Series

Integrated Services

Routers Regulatory

Compliance and Safety Information document that
accompanied the router.

Safety compliance

UL 60950; CAN/CSA C22.2 No. 60950-00;
EN 60950; AS/NZS 3260