Environmental reporting features – Cisco 3800 Series User Manual

Page 69

Advertising
background image

Solving Problems

39

Troubleshooting Cisco 3800 Series Routers

OL-5972-01

With the power switch on and the SYS LED steady green, do the fans operate?

If yes, the power system is functioning.

If no, check the fans.

With the power switch on and the SYS PWR LED (Cisco 3825) or SYS PWR1 or SYS PWR2 LED
(Cisco 3845) off, do the fans operate?

If yes, the router is receiving power. The fans are connected directly to the DC outputs of the
power supply.

If no, check the power source and power cable.

Does the router shut down after being on a short time?

Check for an environmentally induced shutdown. See the next section, “

Environmental

Reporting Features

.”

Check the environmental site requirements in the

“General Site Requirements” section on

page 3

of “

Preinstallation Requirements and Planning for Cisco 3800 Series Routers

.”

Check for a power supply failure by inspecting the SYS PWR LED on the Cisco 3825 router,
or the SYS PWR1 or SYS PWR2 LED on the Cisco 3845 router (depending on which power
supply is active). If the LED is green, the power supply is functional.

Router partially boots, but LEDs do not come on.

Check for a power supply failure by inspecting the SYS PWR LED on the Cisco 3825 router or
the SYS PWR1 LED or SYS PWR2 LED on the Cisco 3845 router (depending on which power
supply is active). If the LED is green, the power supply is functional.

If the SYS PWR LED is not on, see the

“Obtaining Technical Assistance” section on page 12

of

“Introduction to Cisco 3800 Series Routers Hardware Documentation”

for information about

customer service. For warranty information, see the

“Cisco 90-Day Limited Hardware Warranty

Terms” section on page 10

of “

Introduction to Cisco 3800 Series Routers Hardware

Documentation

.”

Environmental Reporting Features

If the router is operating at an abnormally high temperature, the following message is displayed on the
console screen:

System detected OVERTEMPERATURE condition. Please resolve cooling problem immediately!

Some causes of abnormally high router temperature are:

Fan failure

Air conditioning failure in the room

Air blockage to cooling vents

Take steps to correct the problem. See also the

“Site Environment” section on page 4

and the

“Equipment Racks” section on page 5

of “

Preinstallation Requirements and Planning for Cisco 3800

Series Routers

.”

Advertising