This is an example of the output of the show environment command for a Cisco 3845 router that has
one AC power supply with IP phone power output installed:

Router# show environment

SYS PS1 is present

Fan status: Normal

Input Voltage status: Normal

DC Output Voltage status: Normal

Type: AC

Thermal status: Normal

SYS PS2 is absent

AUX (-48V) PS1 is present

AUX (-48V) PS2 is absent

Fan 1 Normal

Fan 2 Normal

Fan 3 Normal

Fan Speed is Normal

Alert settings:

Intake temperature warning: Enabled, Threshold: 50

Core temperature warning: Enabled, Threshold: 70 (CPU: 90)

Board Temperature: Normal

Internal-ambient temperature = 31, Normal

CPU temperature = 50, Normal

Intake temperature = 25, Normal

Backplane temperature = 24, Normal

Voltage 1(3300) is Normal, Current voltage = 3284 mV

Voltage 2(5150) is Normal, Current voltage = 5210 mV

Voltage 3(2500) is Normal, Current voltage = 2549 mV

Voltage 4(1200) is Normal, Current voltage = 1215 mV

Error Messages

This section describes error messages that may appear on an external console screen. (For more
information about consoles, see the

“Connecting a Console or Modem” section on page 29

of

“

Connecting Cables to Cisco 3800 Series Routers

.”)

Cisco IOS software checks the system once every 30 seconds. If an error still exists, the error message
is displayed again; if the error has cleared, a recovery message is displayed.

Error Message System detected OVERTEMPERATURE condition. Please resolve cooling
problem immediately!

Explanation

The router is operating at a temperature higher than the user-set threshold, possibly

caused by fan failure, air-conditioning failure in the room, or air blockage to cooling vents.

Recommended Action

Make sure that the ambient room temperature does not exceed 40 degrees C

and that airflow to the router is not blocked. See the

“Site Environment” section on page 4

and the

“Equipment Racks” section on page 5

of “

Preinstallation Requirements and Planning for

Cisco 3800 Series Routers

.”

If this condition persists, the power-supply thermal monitor automatically shuts down the router.
Call your Cisco technical support representative for help, if necessary.