Connecting routers to backup power, Connecting routers to backup power” section on, Figure 19 – Cisco 3800 Series User Manual

Page 57: Source a and

Advertising
background image

Power Connections

27

Connecting Cables to Cisco 3800 Series Routers

OL-5970-02

Figure 19

Source A and Source B Wired with Opposite-Polarity Grounds

Connecting Routers to Backup Power

The Cisco 3845 router accommodates two hot-swappable power supplies in bays at the front of the
router. A single power supply meets router requirements. The second power supply provides
redundancy, load sharing, and increased router availability. Either power supply can be removed without
affecting router operation. Any combination of two power supplies is permitted.

For instructions for installing a second power supply in a Cisco 3845 router, see the “

Installing and

Upgrading Internal Components in Cisco 3800 Series Routers

” section.

The Cisco 3825 router has one internal power supply and provides a connector to an optional
Cisco Redundant Power System (RPS) external backup source.

Figure 20

and

Figure 21

illustrate this

connection. Use a flat-blade screwdriver to pry off the door over the RPS connector before connecting
the cable. See the

Cisco RPS-675 Hardware Installation Guide

for complete RPS power connection

instructions.

Caution

Before connecting the RPS to the router, make sure that either the RPS is in standby mode or the RPS
AC power is disconnected. Connecting the RPS to AC power automatically places the RPS in
active mode.

A-

127041

A+

B+

B-

Va

Vb

+

+

A-

A+

B+

B-

Va

Vb

+

+