3. Install the two new One Touch fittings in the two locations where the last fittings were just removed. See

illustration. You will need to place an open end wrench on the brass "T" fitting to keep it from moving while
installing the new fitting on the right. Do not over tighten these fittings.

Install new
fitting here

Place wrench here
to avoid movement
from this fitting while
installing new fitting.

Install new
fitting here

Art # A-07617

New Fittings in place. Some items removed for clarity

4. Reinstall the two black tubing pieces removed in step 1, making sure they seat all the way. You should feel this

when done properly.