SECTION TSM

270.1

ISSUE

A

PAGE 4 OF 12

SECTION TSM

270.1

ISSUE

A

PAGE 5 OF 12

The Industrial Lobe series pump can be supplied with a

variety of mechanical sealing configurations and materials.

A cartridge mechanical seal is considered standard

construction.

Complete pump disassembly is not necessary if only the

cartridge seals are being replaced. For seal replacement

only, access to the seals from the head end of the pump is

more efficient.

General installation and replacement instructions for the

sealing options are provided. It is also recommended to

review the seal manufacture’s instructions.

For complete pump disassembly and assembly instructions

see pages 7 through 9.

MECHANICAL SEAL INFORMATION

DANGER!

Before starting pump, be sure all drive equipment

guards are in place.
Failure to properly mount guards may result in seri-

ous injury or death.

DANGER !

Before opening any Viking pump liquid chamber

(pumping chamber, reservoir, etc.) be sure:

1. That any pressure in the chamber has been

completely vented through the suction or

discharge lines or other appropriate openings or

connections.

2. That the driving means (motor, turbine, engine, etc.)

has been “locked out” or made non-operational so

that it cannot be started while work is being done

on pump.

3. That you know what liquid the pump has been

handling and the precautions necessary to

safely handle the liquid. Obtain a material safety

data sheet (MSDS) for the liquid to be sure these

precautions are understood.

4. That

the timing gearbox to cool before handling

the pump. The oil will become very hot during

normal operation. Allow the timing gearbox oil.

Failure to follow above listed precautionary mea-

sures may result in serious injury or death.

FIGURE 4

Cartridge Mechanical Seal Replacement

Only

REMOVAL

1.Remove the cover plate capscrews and remove the

cover plate from the bracket.

2.Loosen the seal setscrews and remove the seal gland

capscrews and washers.

3.Remove the head capscrews and head.
4.Remove the lobe snap rings, lobes and keys.
5.Remove the capscrews connecting the bracket to the

casing, and pull the casing from the bracket.

6.Remove the seals.

INSTALLATION

1.Lubricate the seal ID and pump shaft with an appropriate

lubricant. Slide each seal onto a shaft, and place about

5.25” past the step on the shaft.

2.Replace the casing, being careful not to damage the

bushings on the steps of the shafts, and secure to the

bracket with capscrews.

3.Install the keys and lobes, and secure with the snap rings.

The flat side of the snap ring should face the lobe.

4.Install the O-ring, head and capscrews.
5.Slide the seals towards the casing until the glands

contact the stuffing box face.

6.Secure the seal glands to the casing with washers and

capscrews. Torque the bracket, head and finally the seal

gland capscrews according to Table 2 on page 3.

7.Tighten the seal setscrews.

For optional cartridge mechanical seals that have setting

clips, remove them.

8.Replace the cover plate and capscrews on the bracket.

WARNING:

Do not use the circulation tubing to lift the pump or

casing. Make sure the bracket is secured to a work

bench or other stable work surface before working

on the pump.

Advertising