Optional packing replacement only, Labyrinth seal, Optional cartridge lipseal seal replacement only – Viking Pump TSM270.1: RL 16 and 25 Standard User Manual

Page 6

Advertising
background image

SECTION TSM

270.1

ISSUE

A

PAGE 6 OF 12

SECTION TSM

270.1

ISSUE

A

PAGE 7 OF 12

Optional Packing Replacement Only

REMOVAL

1. Remove the packing gland capscrews.
2. If the pump bracket is still assembled, there is enough

room to slide the packing gland back and pull out

the packing with a packing hook, without further

disassembly.

INSTALLATION

1. Clean the stuffing box thoroughly and check the shaft for

smoothness. Scored shafts should be replaced.

2. Lubricate the packing rings with an appropriate

lubricant. Install and seat each ring of packing one at a

time, staggering the ring joints 90° apart. Push each ring

in by hand using the packing gland or by tightening two

opposite packing gland capscrews.

3. Install the packing gland washers and capscrews.

Tighten the packing gland until it becomes snug. Do not

over-tighten.

4. On start-up of the pump, carefully tighten the gland

to reduce leakage until a desired leakage rate is

obtained. Excess leakage during the break-in period

is necessary to help lubricate and cool the packing. A

maximum adjustment of approximately 1/8 turn at a time

is recommended. If during this period heating occurs,

back off the gland and allow to run until stuffing box

cools. Then, begin readjustment.

NOTE: Some leakage is required for packing lubrication.

The amount will vary depending on the application. Consult

your authorized Viking representative for more information.

Labyrinth Seal

All labyrinth seals contain 4 common parts:
Stationary Element

Stationary O-ring

Rotating Element

Rotating O-ring
It is recommended to replace any O-rings that are removed

from their initial seat. It is recommended to replace the

entire seal if the stationary and rotating elements become

separated.

FIGURE 6

REMOVAL

1.Remove the cover plate capscrews and remove the

cover plate from the bracket.

2.Loosen the seal setscrews and remove the seal gland

capscrews and washers.

3.Remove the head capscrews and head.
4.Remove the lobe snap rings, lobes and keys.
5.Remove the capscrews connecting the bracket to the

casing, and pull the casing from the bracket.

6.Remove the seals.

INSTALLATION

1.Lubricate the seal ID and pump shaft with an

appropriate lubricant. Slide each seal onto a

shaft, and place 5.25” past the step on the shaft.

2.Replace the casing, being careful not to damage the

bushings on the steps of the shafts, and secure to the

bracket with capscrews.

3.Install the keys and lobes, and secure with the snap

rings. The flat side of the snap ring should face the lobe.

4.Install the O-ring, head and capscrews.

5.Slide the seals towards the casing until the glands contact

the stuffing box face. Turn the centering tabs inward.

6.Secure the seal glands to the casing with washers and

capscrews. Torque the bracket, head and finally the

seal gland capscrews according to Table 2 on page 3.

7.Tighten the seal setscrews and turn the centering tabs

outward.

8.Replace the cover plate and capscrews on the bracket.

FIGURE 5

NOTE: Good radial alignment is required for proper

operation of the seals. This is accomplished by the use of

centering tabs provided with each seal. Turn the tabs inward

when installing or removing the seal. Turn them outward for

normal operation of the pump.

Optional Cartridge Lipseal Seal Replacement

Only

Advertising