Mechanical seal option, Danger – Viking Pump TSM312: G-N 32/432 User Manual

Page 8

Advertising
background image

SECTION TSM 312

ISSUE

G

PAGE 8 OF 11

FIgURE 14

FIgURE 13 - gaSKET TaBLE

7. Place packing retainer washer in bottom of packing

chamber and pack pump with new packing. Use packing

suitable for liquid being pumped. Install packing,

staggering the joints from one side of shaft to other.

Lubricate packing rings with oil, grease or graphite to

aid assembly. A length of pipe will help to seat each

packing ring.

NOTE: If the pump has a lantern ring it must be located

below the grease fitting. The grease fitting may be removed

to facilitate positioning of the lantern ring.
8. Install packing gland, capscrews and nuts.

NOTE: Pump may be equipped with a 2-piece split packing

gland.

See Figure 14.

Install the mechanical seal: Place the set-collar on the shaft

and tighten setscrew.

See Figure 15, page 8 for set-collar

location.
The seal used in this pump is simple to install and good

performance will result if care is taken during installation.
The principle of the mechanical seal is contact between the

rotary and stationary members. These parts are lapped to

a high finish and their seating effectiveness depends on

complete contact.
Once rotating position of mechanical seal is installed on

rotor shaft, it is necessary to assemble parts as quickly as

possible to ensure seal does not stick to shaft in the wrong

axial position. The seal should be expected to stick to shaft

after several minutes setting time.
1. Never touch sealing faces with anything except clean

hands or clean cloth. Minute particles can scratch the

seal faces and cause leakage.

2. The spring washer and spring must be put on the shaft

first and in that order.

(See Figure 15, page 8).

3. Spread a film of lubricating oil on the inside diameter

of the synthetic rubber bellows. Check the end of the

pump shaft for sharp burrs or edges which might cut the

bellows. Slide the seal rotary member over the shaft and

up against the spring.

4. Coat the synthetic rubber seal seat with lubricating oil

and push the seal seat into the end cap. Put the end

cap gasket on the end of the casing. Slide end cap over

the shaft and flush both the seal seat and carbon wear

ring in the seal rotary member with oil. Push the end cap

up until the mating surfaces of the seal meet. Install the

capscrews and tighten evenly.

MECHaNICaL SEaL OPTION

DaNgER !

Before starting pump, be sure all drive

equipment guards are in place.
Failure to properly mount guards may

result in serious injury or death.

SPRINg WIRE RETaINER

CLIP (2 REQUIRED)

SPLIT PaCKINg gLaND

(2 REQUIRED)

CaPSCREW

(2 REQUIRED)

PUMP

MODEL

NORMaL

aMOUNT

USED

ONE SET OF gaSKETS

CONSISTS OF THE

FOLLOWINg

STaNDaRD

END

CLEaRaNCE

G32

G432

.010” - .015”

2 - .006”

1 - .005”

2 - .002”

.003”

H, HL32

H, HL432

.010” - .015”

2 - .006”

2 - .002”

.003”

J, K, KK32 .015” - .020”

1 - .015”

1 - .010”

1 - .006”

.005”

L, LQ, LL32 .025” - .030”

1 - .015”

1 - .010”

1 - .006”

.005”

Q32

.012” - .030”

2 - .015”

1 - .006”

.010”

M, N32

.015” - .036”

2 - .015”

1 - .006”

.015”