Disassembly / assembly - e05 and e12 disassembly – Viking Pump TSM344: CMD Mag Drive User Manual

Page 12

Advertising
background image

SECTION TSM 344

ISSUE

F

PAGE 12 OF 24

2. Place the pump assembly (motor spool down) on the

work surface.

3. Remove the six bolts and washers (items 3, 4), remove

front cover (item 5) and nut plates (item 28) as shown.

4. Remove the bearings (item 10), gear/shaft assemblies

(items 12, 13) and housing liner (item 11) as shown.

These parts, along with the four O-Rings make up a

standard CMD Series repair kit. Check parts for wear

and replace with a repair kit as required.

5. Remove the eight mounting bolts and washers (items

16, 17) holding the center housing (item 14) to the motor

spool (item 20). Remove the center housing and retaining

plates (item 32).

6. Remove all O-Rings from the center housing and front

cover. There are two O-Rings in the center housing

(items 6, 15) and one in the front cover (item 9) as

shown.

FIGURE 19

FIGURE 20

FIGURE 21

FIGURE 22

wARNING !

Before performing any maintenance

requiring pump disassembly, be sure to

relieve pressure from the piping system

and, where hazardous process materials

are involved, render the pump safe

to personnel and the environment by

cleaning and chemically neutralizing as

appropriate. wear protective clothing and

equipment as appropriate.

■ Close all suction and discharge valves.

■ Disconnect power source to motor.

■ Flush and drain pump.

■ Remove piping (optional for repair kit).

NOTE: The can area will not fully drain and will contain

some process fluid.

1. Remove the four motor bolts and washers (items 22, 23)

and slide the entire pump straight off the motor.

DISASSEMBLY / ASSEMBLY -

E05 AND E12

DISASSEMBLY

CAUTION !

Rare earth magnets used in couplings

have extremely strong magnetic fields

capable of changing performance or

damaging items such as the following:

Pacemakers

Metal Implants

watches

Computers & Disks

Credit Cards

Completely assembled magnetic

couplings will not affect items listed

above - only disassembled components.
There are no known harmful effects of

these magnetic fields on the human

body.