Disassembly / assembly - e02 disassembly – Viking Pump TSM344: CMD Mag Drive User Manual

Page 9

Advertising
background image

SECTION TSM 344

ISSUE

F

PAGE 9 OF 24

wARNING !

Before performing any maintenance

requiring pump disassembly, be sure to

relieve pressure from the piping system

and, where hazardous process materials

are involved, render the pump safe

to personnel and the environment by

cleaning and chemically neutralizing as

appropriate. wear protective clothing and

equipment as appropriate.

FIGURE 4

■ Close all suction and discharge valves.

■ Disconnect the power source to the motor.

■ Flush and drain the pump.

■ Remove the piping (optional for repair kit).

NOTE: The canister area will not fully drain and will

contain some process fluid.

1. Remove the four motor bolts and washers (items 22, 23)

and slide the entire pump straight off the motor.

2. Place the pump assembly (motor spool down) on the

work surface.

3. Remove the six bolts and flat washers (items 3, 4) and

remove the front cover (item 5) as shown.

4. Remove the bearings (item 10), gear/shaft assemblies

(items 12, 13) and housing liner (item 11) as shown.

These parts, along with the three O-Rings make up a

standard CMD Series repair kit. Check the parts for

wear and replace with a repair kit as required.

5. Remove the two remaining bolts (item 7) to detach the

center housing (item 14).

6. Remove all O-Rings from the center housing and front

cover. There are two in the center housing (items 6 and

15) and one in the front cover (item 9) as shown.

7. Remove the eight mounting bolts and washers (items

16, 17) holding the adapter plate (item 18) to the motor

spool (item 20) and detach the adapter plate.

FIGURE 5

FIGURE 6

FIGURE 7

DISASSEMBLY / ASSEMBLY -

E02

DISASSEMBLY

CAUTION !

Rare earth magnets used in couplings

have extremely strong magnetic fields

capable of changing performance or

damaging items such as the following:

Pacemakers

Metal Implants

watches

Computers & Disks

Credit Cards

Completely assembled magnetic

couplings will not affect items listed

above - only disassembled components.
There are no known harmful effects of

these magnetic fields on the human

body.