Bolt torque recommendations – Viking Pump TSM344: CMD Mag Drive User Manual

Page 20

Advertising
background image

SECTION TSM 344

ISSUE

F

PAGE 20 OF 24

Pump Size

Bolt Position

Bolt Size

Recommended Torque

in-lbs

N-m

E02

Front Cover / Housing

10 - 32

15

20

Housing Adaptor -to- Spool

1/4 - 20

48

65

Spool -to- Motor Adaptor or Motor

3/8 - 16

72

98

Motor Adaptor -to- Motor

56C

3/8 - 16

72

98

63 B14

M5 - 0.80

24

33

80 B14

M6 - 1.00

48

65

E05 and E12

Front Cover

1/4 - 20

48

65

Housing -to- Spool

1/4 - 20

48

65

Spool -to- Motor Adaptor or Motor

3/8 - 16

72

98

Motor Adaptor -to- Motor

56C

3/8 - 16

72

98

143TC - 182C

3/8 - 16

72

98

63 B14

M5 - 0.80

24

33

80 B14

M6 - 1.00

48

65

E25

Front Cover

1/4 - 20

72

98

Housing -to- Spool

3/8 - 16

120

163

Spool -to- Motor Adaptor

3/8 - 16

120

163

Base Mount -to- Spool

3/8 - 16

120

163

Flange Bolts (min. to seal)

Varies

120

163

Motor Adaptor -to- Motor

56C

72

98

143TC - 182C

3/8 - 16

120

163

100 - 112 B14

M8 - 1.25

120

163

E75 and E125

Front Cover

3/8 - 16

120

163

Housing -to- Spool

3/8 - 16

120

163

Spool -to- Motor Adaptor

3/8 - 16

120

163

Base Mount -to- Spool

3/8 - 16

120

163

Flange Bolts (min. to seal)

Varies

120

163

Motor Adaptor -to- Motor

143TC - 182C

3/8 - 16

120

163

182TC - 184TC

1/2 - 13

120

163

100 - 112 B14

M8 - 1.25

120

163

BOLT TORQUE RECOMMENDATIONS