Lubrication, Storage, Periodic oil changes – Viking Pump TSM615: In-line Gear Reducers User Manual

Page 2: Caution

Advertising
background image

SECTION TSM 615

ISSUE

I

PAGE 2 OF 5

LUBRICATION

Gear units are oil-bath lubricated. For applications calling for

speed reducers with vertical shaft orientation, oil coverage

during operation would not be sufficient to ensure correct

lubrication of upper bearings, suitable life lubrication systems

must be used.
Speed reducer sizes 12 - 41 are supplied pre-filled with oil and

do not have oil filling or level plugs. These long-life lubricated

units (using synthetic oil) are capable of operating at an

ambient temperature range of -4°F (-20°C) to 122°F (50°C).

For temperatures below -4°F (-20°C), contact your authorized

distributor or Viking Technical Service.
Speed reducers sizes 51 - 100 require oil filling by the user.

Before start-up, fill with the correct quantity of oil using

Table 1. These quantities are approximate, use the sight

glass on the unit to fill accurately. When filled correctly, the

oil level should be in the center of the sight glass. Choose

the viscosity and type of oil from

Table 2 that is appropriate

for the ambient temperature. Viking highly recommends the

use of synthetic oil as it maintains viscosity properties over a

broader temperature range, shear rates and time. In addition,

synthetic oils usually contain additives that prevent foaming

and rusting, such as Mobil SHC 600 series, Texaco Synlube

CLP series or equivalents. These speed reducers are supplied

with oil fill, level, and drain plugs.
Contact your authorized distributor or Viking Technical Service

for vertical or other mounting arrangements.

Oil Quantity

Size

Pints

Liters

12 *

0.95

.45

22 *

1.69

0.80

32 *

3.0

1.4

36 *

3.4

1.6

41 *

4.6

2.2

51

6.6

3.1

61

8.9

4.2

70

14

6.5

80

23

11

90

40

19

100

57

27

* Indicates Life Lubricated

Table 2

Ambient

Temperature

32 – 70° F

(0 – 20°C)

-4 – 70° F

(-20 – 20°C)

70 – 104° F

(20 – 40°C)

Duty

Load

Mineral

Oil

ISO VG

Synthetic

Oil

ISO VG

Mineral

Oil

ISO VG

Synthetic Oil

ISO VG

Light Duty

150

150

220

220

Medium Duty

150

150

320

220

Heavy Duty

220

220

460

320

Periodic Oil Changes

Periodic oil changes are not required for sizes 12 - 41 as

they are lubricated for life with synthetic oil. The remaining

sizes 51 – 100 are designed for oil lubrication and have oil fill,

level, and drain plugs, see

“Plug Locations”. Users should

replace the oil based on

Table 3 and following the directions

in

“Lubrication”.

CAUTION !

Sizes 12, 22, 32, 36, 41 are pre-filled with

synthetic lubricant when shipped and require

no additional lubricant. These sizes have

no oil filling or level plugs. Sizes 51 – 100

require filling with correct amount and type of

lubricant prior to use. Operating reducer

without the proper type and amount of

lubricant for even a short period of time may

cause damage.

STORAGE

Observe the following instructions to ensure correct storage of

products:
A) Do not store outdoors, in areas exposed to weather or with

excessive humidity.

B) Always place boards, wood, or other material between the

products and the floor. The gearbox should not have direct

contact with the floor.

C) For long term storage (over 60 days), all machined surfaces

such as flanges, shafts and couplings must be protected

with a suitable rust inhibiting product (Mobilarma 248 or

equivalent).

D) The following measures must be taken when products are

stored for a period exceeding 6 months:
For life lubricated products, the machined areas must be

greased to prevent oxidation.

In addition to above, products originally supplied without

oil must be positioned with the breather plug at the highest

point and filled with oil.

Before operating the speed reducer, restore the correct

quantity of oil.

Table 1

It must be emphasized that these quantities are only

indicative and users should check the correct level through

the sight glass.

Advertising