SECTION TSM 615

ISSUE

I

PAGE 3 OF 5

Oil

Temperature

Oil Change Interval (Hrs)

Mineral

Oil

Synthetic

Oil

<150° F (<65°C)

8000

25000

150-175°F (65 – 80°C)

4000

15000

175–200°F (80–95°C)

2000

12500

PLUG LOCATIONS

The breather plug, fill/breather plug, level plug and drain plug

locations are shown below. The C12-C41 reducers are filled

and shipped with a synthetic oil and, therefore, do not have

fill or level plugs. The C51-C100 reducers must be filled at

installation and have a level plug mounted on the side. The

plug locations are shown below.

HS

NEMA and IEC

C12- C41

C51-C61

C70-C100

Symbols

C-12

C36, C41

C22, C32

C36, C41

Breather Plug

Fill / Breather Plug

Level Plug / Sight Glass

Drain Plug

Table 3

Breather units are not installed at the factory. Remove the

breather plug and replace with the breather unit (typically

taped to the side of the unit).