Plug locations, Symbols – Viking Pump TSM615: In-line Gear Reducers User Manual
Page 3
SECTION TSM 615
ISSUE
I
PAGE 3 OF 5
Oil
Temperature
Oil Change Interval (Hrs)
Mineral
Oil
Synthetic
Oil
<150° F (<65°C)
8000
25000
150-175°F (65 – 80°C)
4000
15000
175–200°F (80–95°C)
2000
12500
PLUG LOCATIONS
The breather plug, fill/breather plug, level plug and drain plug
locations are shown below. The C12-C41 reducers are filled
and shipped with a synthetic oil and, therefore, do not have
fill or level plugs. The C51-C100 reducers must be filled at
installation and have a level plug mounted on the side. The
plug locations are shown below.
HS
NEMA and IEC
C12- C41
C51-C61
C70-C100
Symbols
C-12
C36, C41
C22, C32
C36, C41
Breather Plug
Fill / Breather Plug
Level Plug / Sight Glass
Drain Plug
Table 3
Breather units are not installed at the factory. Remove the
breather plug and replace with the breather unit (typically
taped to the side of the unit).