6 Operating the device

6.1 Operating principle

Fig. 6: Control elements on the WX 2

Keys

Operation

Function

Control key 1, 2, 3,

4

Briefly press key 1, 2, 3 or 4

once

The fixed temperature (23/24/32/33)* becomes

the active set-point temperature (26/30)*.

(tool channel: key 1, 2 = left; key 3, 4 = right)

Scroll within the Parameter menu

Press and hold down key 1, 2,

3 or 4

for 3 sec.

The active set-point temperature is saved as

the fixed temperature under the key being

pressed (1, 2, 3 or 4).

Press and hold down keys 1

and 2 or 3 and 4

simultaneously

1 and 2 = left channel (12)* is disabled or

opened

3 and 4 = right channel (9)* is disabled or

opened

Press and hold

down keys 13 and 1

or 2

keys 13 and 1 or 13 and 2

simultaneously

Open Parameter menu

Press and hold

down keys 6 and 3

or 4

keys 6 and 3 or 6 and 4

simultaneously

Open Parameter menu

Selection key 6, 13 Briefly press key 6 or 13 once − Select auxiliary device, this being a

requirement for opening the parameter

settings of the auxiliary device (e.g. WFE)

Press and hold down keys 6

and 13 for 3 sec.

The set-point temperature window opens

Key 6

Briefly press key 6 once

Exit parameter menu

Turn-and-click

wheel 7

Move your finger over the

turn-and-click wheel

Select/set value

Navigate within a menu

Click left or right

The set-point temperature window opens for

the soldering tool connected on the left/right

Enter key 8

Briefly press key 8 once

Confirm value/selection

*) see also overview diagrams (Fig. 1 and Fig. 2).