8 Care and maintenance of the WX 2

Z

Clean the operator panel, if dirty, using a suitable cleaning cloth.

Z

Seal ports which are not in use with covering caps.

9 Error messages and error clearance

Message/symptom

Possible cause

Remedial measures

Display: "- - -

Tool has not been detected

Tool defective

Check connection of tool to

device

Check connected tool

No display function

(display OFF)

No mains supply voltage

Turn on mains power switch

Check mains supply voltage

Check device fuse

OFF

Channel cannot be switched

on

Overload cut-out

Only one soldering iron can be

operated.

10 Accessories

T005 29 202 99 WXP 120 Soldering set with holder WDH 10
T005 29 206 99 WXP 200 Soldering set with holder WDH 31
T005 13 178 99 WXMT Micro desoldering tweezers with holder

WDH 60

T005 29 204 99 WXMP Micro soldering iron with holder WDH 50
T005 15 121 99 WDH 10 Safety holder for WXP 120
T005 15 158 98 WDH 31 Safety holder for WXP 200
T005 15 156 99 WDH 50 Safety holder for WXMP
T005 15 169 99 WDH 60 Safety holder for WXMT
T005 36 476 99 WFE 20D 230 V solder fume extractor
T005 36 266 99 WFE 2S 230 V portable extractor unit
T005 36 256 99 WFE 4S 230 V mobile extractor unit
T005 36 586 99 WFE 8S 230 V mobile extractor unit
T005 33 648 99 WHP 1000 1000 W preheating plate
T005 33 386 99 WHP 3000 600 W infrared preheating plate
T005 33 646 99 WHP 3000 1200 W infrared preheating plate
T005 87 647 10 WX Connecting cable
T005 87 647 11 WX PC adaptor
T005 87 647 12 WX Adaptor for WFE/WHP
For details of other accessories, please refer to the operating

instructions for the individual soldering iron sets.