6.5 Setting the temperature individually

Please observe the overview diagrams (Fig. 1 and Fig. 2).

Setting the fixed temperature
1. Press the required selection key 6 or 13.

The current set-point temperature is shown on the display (see

Fig. 13).

2. Set the required set-point temperature with the turn-and-click

wheel (7).

3. Confirm the value with the Enter key (8).
4. Press and hold down the required control key 1, 2, 3 or 4 for

3 sec. in order to save the current set-point as a fixed

temperature (under the key being pressed).

Note You can find further information about the intelligent tool (e.g. fixed

temperature, factory settings) in the relevant operating instructions.

Select the temperature with control keys 1, 2, 3 and 4
The temperature set-point can be set by selecting two preset

temperature values (fixed temperatures) per tool.
Z

Press the required temperature key 1, 2, 3 and 4.

The tool adjusts to the required temperature.

6.6 Switching the channel on/off

Please observe the overview diagrams (Fig. 1 and Fig. 2).

Left channel (12)
Z

Press control keys 1 and 2 simultaneously to switch the tool

on/off.

Right channel (9)
Z

Press control keys 3 and 4 simultaneously in order to switch the

tool on/off.

Note The tool is switched on as soon it is removed from the holder. A

motion sensor is integrated in the tool.

Channel disabled
If a channel is disabled, the display will read "OFF" (19).