7 Setting parameters via the parameter

menu

The parameter menu is subdivided into two areas:
Parameter
Setting options:

- Standby temperature
- Standby time (temperature deactivation)
- AUTO OFF time (automatic switch-off time)
- Offset (temperature offset)
- Control response
- Process window

Station parameters
Setting options:

- Language
- Temperature version °C/°F (temperature units)
- Password (lock function)
- Touchtones on/off
- LCD contrast
- LCD background brightness
- Screen saver

7.1 Set parameters

Please observe the overview diagrams (Fig. 1 and Fig. 2).

Setting the standby temperature

Note The soldering tools have a usage detector (sensor) in the handle

which automatically starts the cooling cycle when the soldering tool

is not in use.
You will find further information about the intelligent tool in the

relevant operating instructions.
The standby temperature is automatically set after a temperature

deactivation.
1. Call up the parameter menu.
2. Select the menu option Standby temperature.
3. Set the standby temperature set-point with the turn-and-click

wheel (7).

4. Confirm the value with the Enter key (8).
5. Exit the parameter menu with key 6.