6.4 Connecting the soldering tool

Please observe the overview diagrams (Fig. 1 and Fig. 2).
1. Check to see if the required soldering tool is correctly connected

(see "Starting up the device" on page 7).

2. Switch on the device at the mains power switch (18).

The display shows the actual temperature value (29), the set-

point temperature (26/30) and the fixed temperatures (23/24 or

32/33) of the connected tool. The set-point temperature and fixed

temperatures are stored in the tool. The actual temperature value

increases to the set-point temperature (= soldering tool is heated

up).

Note If you want to connect two tools simultaneously to WX 2, please

note the overload cut-out.

Note
You will find further connection versions on page 21.

Please adhere to the operating instructions of the connected

devices.

Overload cut-out (240 W)
If two tools are simultaneously connected to WX 2 and together have

a power demand of greater than 240 W, an overload cut-out will

occur (see Fig. 12).

Only one tool/channel can be used at a time.
Activating the soldering tool/channel:
Z

Press the required control keys 1 and 2 (left channel (12)) or 3

and 4 (right channel (9)) simultaneously.

or–

Remove the required soldering iron from its holder.