Weller WX2 User Manual

Page 38

Advertising
background image

14-20

WX 2

Fig. 17

Fig. 19

Fig. 20

Fig. 18

Set the temperature deactivation value (standby time)
When the soldering tool is not in use, the temperature is reduced to

the standby temperature after the set standby time has elapsed.

Standby mode is indicated as a flashing actual value and the display

reads "Standby" (20).
Press control key 1, 2, 3 or 4 to exit Standby mode. The sensor

integrated tool detects the change in state and deactivates Standby

mode as soon as the tool is moved.
Setting the standby time:
1. Call up the parameter menu.
2. Select and confirm the menu option Standby time.

3. Set the required standby time with the turn-and-click wheel (7).

The following standby settings are possible:

"OFF" = "0 min": standby time is deactivated (factory setting)

"ON" = "1-99 min": standby time, individually adjustable

4. Confirm the value with the Enter key (8).
Select further setting parameters in the menu

or

exit the parameter menu with key 6.

Note In the case of soldering work with low heat requirements, the

reliability of the standby function may be impaired.

Setting the automatic switch-off time (AUTO-OFF)
When the soldering tool is not in use, the soldering tool

heater is switched off when the AUTO OFF time expires.
Temperature deactivation is performed independently of the set

standby function. The actual temperature is indicated by flashing

LED and serves as a residual heat display. The display reads

"OFF" (19).
1. Call up the parameter menu.
2. Select and confirm the menu option AUTO-OFF time .
3. Set the required AUTO-OFF time with the turn-and-click wheel

(7).
The following AUTO-OFF time settings are possible:

"OFF" = "0 min": AUTO OFF function is deactivated (factory

setting)

"ON" = "1-999 min": AUTO-OFF time, can be set individually.

4. Confirm the period with the Enter key (8).
Select further setting parameters in the menu or

exit the parameter menu with key 6 .

Note To reset the STANDBY and AUTO-OFF modes:

Press control key 1, 2, 3 or 4 (if no tool holder is in use) or remove

the soldering tool from the holder.