About the topology-dependent parameters – Cisco OL-7822-06 User Manual

Page 40

Advertising
background image

4-20

Cisco Service Control Engine 1000 2xGBE Quick Start Guide

OL-7822-06

Chapter 4 Connect the Management Interfaces and Perform Initial System Configuration

Perform the Initial System Configuration

Would you like to add another SNMP SET community? [no]:

Would you like to configure SNMP trap managers? [no]: y

Enter SNMP trap manager IP address: 10.1.1.253

Enter SNMP trap manager community string: public

Enter trap manager SNMP version: 2c

Would you like to add another SNMP trap manager? [no]:

Enable the ‘Authentication Failure’ trap [no]: y

Enable SCE enterprise traps []: y

Enter system administrator contact name []: John Smith

Step 9: Configuring the Topology-Dependent Parameters

About the Topology-Dependent Parameters, page 4-20

Examples, page 4-21

About the Topology-Dependent Parameters

The topology configuration menu is a series of guided questions relating to the deployment of the SCE
1000 in the network and its mode of operation. Values for the parameters are configured based on the
user answers.

The correct value for each parameter must be ascertained before configuring the system to make sure
that the system will function in the desired manner.

There are three topology-related parameters:

Connection mode — Can be either Inline or Receive-only, depending on the physical installation
of the SCE 1000.

Bypass state when the SCE 1000 is not operational (on-failure) — This parameter determines
whether the system cuts the traffic or bypasses it when the SCE 1000 has failed.

Status after reboot caused by fatal error or abnormal shutdown — This parameter determines
whether the SCE 1000 returns to normal operational state after a failure.

The procedure described below is a hypothetical presentation of all the questions in the topology
configuration. In actual practice, it is impossible for all questions to be presented in any one
configuration, as this part of the dialog is not linear like the other sections, but branches depending
on the parameter values entered.

Study the examples that follow to understand the procedure for various topologies.

Step 1

Enter the topology configuration menu.

Would you like to enter the Topology configuration menu? [no]: y

Enter your password if prompted.

Type

y

and press press Enter.

The topology configuration dialog begins.

Step 2

Specify the connection mode.

To define inline connection mode, press press Enter.

To define receive-only connection mode, type 2 and press press Enter.

Enter Connection mode:

1- inline

2- receive-only

Enter your choice [1]:

Advertising