Section 2 - Overview

I.

Page 12

1/06/2012 REV 1.10.2

2.11.1 Security Levels

There are three security levels for gaining direct access to the recorder. Security levels are only active if
security is enabled.

The three levels are

Administrator:

Has access to all levels of the recorder menus and systems.

Manager:

Has restricted access. A Manager cannot set up any base level parameters, but can use
existing setups to create alarms, displays and the like.

User:

Can use the recorder only as set up by the Administrator or Manager. A User cannot
change any parameters. A User needs to log in to accept alarms.

User management is an Administrative only function and is controlled in the

System Administrative Menu.

Here the Administrator can set usernames and passwords, disable users, set user expiry times and force a
user to be logged out after a specific time. The number of log in attempts can also be set before the current
user is disabled.

All users need to

log in

to the unit to perform any functions. At each log in the recorder makes a note of the

time and user name and will also log any failed attempts at login. Each user has a unique username and
password. Users may change their passwords at any time at the log in screen.

The unit also saves a copy of the configuration file when the user logs in and when the user logs out. This
way a complete activity log can be generated (by the accompanying Exhibitor software comparing the two
configuration files) and all parameters changed can be reported.

2.11.2 Remote Access Passwords

The user can access the recorder remotely using various methods. Each method is protected by a unique
password. The passwords need to be set up by the Administrator in the

System Administrative Menu

as

follows:

USB Access: Password optional. When accessing the unit via the USB Connection using ActiveSync

TM

or

Vista

TM

Mobile Manager the Administrator can set an optional password which needs to be entered from the

remote computer before access is allowed. This password is set in the

Set ActiveSync Password

menu.

HTTP Access: Password required. When accessing the web server using the Ethernet and a browser the
user has to provide a password. There are two levels of password Admin and User. Users can view the web
pages but only Admin can perform remote functions. These passwords are set in the

Web User Manager

and

the Administrator user name HAS to be Admin.

FTP Access: Password Required. This is the same password used for system access. User access is
permitted and restricted

– files can be downloaded. Admin access is unlimited.

Remote Control over Ethernet: Password Required. These are the same user names and passwords set for
recorder front panel access through the User management option described above.

All access user names and passwords can be set to be the same provided the administrator user name is