Emd gearbox – Wheatheart GHR 80/100 x 31-71ft Augers EMD User Manual

Page 21

Advertising
background image

W

HEATHEART

- G

RAIN

A

UGER

EMD

3. A

SSEMBLY

GHR 80

X

31’-71’ & 100

X

31’-71’

3.5. EMD G

EARBOX

30642 R0

21

3.5. EMD GEARBOX

The EMD auger uses one of three gearbox assembly combinations depending
on the size of the auger. The assembly is shipped with the appropriate mounting
plate or gearbox mount and chain coupler in place.

¨

Gearbox mounting procedure for the following augers (Figure 3.7):

• 8” x 31’

1. Remove chain and

secure half of the
chain coupler to the
driveshaft using a
Woodruff key.

2. Place

gearbox

assembly on auger
tube leaving a
minimum 1/16”
clearance between
chain coupler
sprockets.

Maintain a minimum 1/16”
clearance between chain
coupler sprockets.

3. Secure

gearbox

assembly to auger
tube with half tube
clamps and four

7/16” x 1" bolts and
locknuts.

The gearbox input on 8" x
31’ is located on the left side of
the auger.

Gearbox mounting procedure
for the following augers
(Figure
3.8):

• 8” x 36’
• 8” x 41’
• 8” x 46’
• 8” x 51’

4. Remove chain and secure

half of the chain coupler to
the driveshaft using a
Woodruff key.

Figure 3.7

Important:

Figure 3.8

Note:

¨

Advertising