5.2. DRIVES & LOCKOUTS

This unit can be equipped with a gas motor / PTO driving a hydraulic pump or a
tractor / skid steer loader supplying the hydraulic power to the machine’s
hydraulic valves.

Before performing any maintenance or servicing, ensure that the ignition key is
removed or the power source is locked out, and the post pounder mast is in the
down position.

5.3. START-UP & BREAK-IN

Although there are no operational restrictions on the machine when used for the
first time, it is recommended that the following mechanical items be checked:

B

EFORE

S

TARTING

:

• Read power unit operational manual.
• Inspect hydraulic hose fittings for leaks. Tighten if necessary, and replace

worn or damaged hoses.

• Inspect hydraulic mount bolts for tightness.

D

URING

THE

F

IRST

F

EW

M

INUTES

:

• Ensure unit is running properly.
• Some air may be trapped in the hydraulic system; slowly activate hydrau-

lic control valves to ensure all air is out of the system.

A

FTER

O

PERATING

F

OR

1/2 H

OUR

O

R

T

RANSPORTING

:

• Retorque all wheel bolts (if applicable).

• Retorque all fasteners and hardware.
• Check all safety decals are installed and legible. Apply new ones if

needed.

• Check all guards are installed and working as intended.

A

FTER

5

AND

10 H

OURS

:

• Check all hydraulic hoses and fittings for leaks. Tighten fittings where

required, and replace worn or damaged hoses.

• Retorque all wheel bolts (if applicable), fasteners, and hardware.

• Grease all zerks; do not grease plastic slides or mast rails.

WARNING

Shut off and remove key or lock out power
source before inspecting or servicing the
machine.