Main tank filling procedures, Caution – Great Plains 3P300 Operator Manual User Manual

Page 36

Advertising
background image

32

3P300 S/N HH1113+

Great Plains Manufacturing, Inc.

500-103M-A

09/14/2009

Main Tank Filling Procedures

Refer to Figure 16
Your Great Plains Sprayer fills the tank from the bottom
of the tank and uses a standard 2 inch cam-lock coupler

to connect to the freshwater hose.

The tank lid is vented and does not need to be opened
for tank water fill operations.

!

CAUTION

When filling the sprayer tank, use a check valve or anti-siphon
device to prevent the previous solution in the tank from infil-
trating into the fresh water source and contaminating it.

IMPORTANT !

Never add chemicals to an empty tank. Before adding
the chemical to the tank, make sure the tank is at least
one half full. The concentrate should not be poured into
an empty tank. Add chemicals at the field. See
page 35.

Note: Tank Straps

The tank straps that wrap around the sprayer tank
may become loose after the first few hours of oper-
ation. This occurs when the tank settles in the sad-
dle. Polyethylene tanks are especially susceptible
to this. Retighten the tank straps to secure the tank.

1.

Check that the hand wash tank is full.

Refer to Figure 13 on page 29
2.

Check that shutoff and cleanout valves (

-

) are

in their “normal” positions for field operations (see
table at right). Set all boom switches to OFF.

!

CAUTION

Do not add the chemical until the sprayer is in the field, just
prior to spraying. When adding the chemical, follow the manu-
facturer’s instructions for mixing the spray solution in order to
achieve the desired application rate.

Figure 16

Quick-Fill Ball Valve

15772

Normal “Field” Valve Settings

Valve

Position

Agitator Selector Valve

Partly OPEN

Manual Throttle Valve

OPEN

Spray/Drain Selector Valve

Front (SPRAY)

Product Valve (Optional, Tank Fill

vs. Induct)

CLOSED
(Centered)

Inductor Valve (Optional, On/Off)

CLOSED

Main Inlet Quick Connect & Valve

(Normally Closed)

CLOSED

Right Tank Inlet Shutoff (Optional,

Normally Closed)

CLOSED

Whirlfilter® Drain Valve (Normally

Closed)

CLOSED

Agitator Inlet Shutoff Valve (Nor-

mally Open)

OPEN

Sight Gauge Shutoff Valve (Nor-

mally Open)

OPEN

1

2

3

4

5

6

7

8

9

10

6

11

6

6

10

Advertising