Inducting chemicals (option), Foam marker tank fill, Inducting chemicals (option) foam marker tank fill – Great Plains 3P300 Operator Manual User Manual

Page 40

Advertising
background image

36

3P300 S/N HH1113+

Great Plains Manufacturing, Inc.

500-103M-A

09/14/2009

Inducting Chemicals (Option)

IMPORTANT !

Always turn pump on before opening inductor shutoff
valve (at step 15). Always turn pump off after closing
inductor shutoff valve (at step 17). If the pump is not
running, the tank can drain back through the inductor.
The inductor lid is vented, and cannot prevent overflow.

Refer to Figure 13 on page 29
9.

Check that the

inductor-outlet/tank-inlet valve

is open.

Refer to Figure 21 and Figure 13 on page 29
10. At the inductor, set valves:

to OFF and
(product valve) from OFF to INDUCT.

11. At the sprayer front, set valves:

(Manual Pressure) to OPEN, and
(Agitation) to OPEN.

12. Under sprayer, set valve:

to Rear (FILL, selecting inductor).

13. Start the pump.

Note: The pump recirculates tank contents through a

venturi beneath the inductor tank.

14. Open the inductor lid.

Note: The inductor lid is vented, and the inductor may be

operated with the lid on or off.

15. Open the inductor shutoff valve

and inspect to

ensure that there is no back-flow of water from the
tank into the inductor. Close the valve.

16. Add the chemical to the inductor tank. Put the lid on

the tank.

17. Open the inductor shutoff valve

. When the

required amount of chemical has been added, and
the inductor tank is empty, close the inductor shutoff
valve

.

18. Turn the pump off.

19. Set the Product valve

to OFF (Centered).

20. Set the left tank inlet valve

to OFF (Centered) or

Front (SPRAY).

Foam Marker Tank Fill

Consult the separate manual provided with the marker
system for information on selecting, mixing, loading and
applying marker foam.

7

Figure 21

Product and Inductor Valves

15802

4

5

5

4

1

2

3

5

5

5

4

3

Advertising