Refer to Figure 59

35. Press FUNCTION. The console beeps and displays

the next screen indicating that the drive is about to
operate, and all personnel must be cleared from the
area near the hydraulic drive, chains and shafts.
There is a danger of entanglement if anyone is in the
drive area.

Moving Chain Entanglement Hazard:
Be sure to verify that no one is near the drive area before
advancing to the next step.

Refer to Figure 59

36. Only after you have verified the drive area is clear,

press the up arrow button to initiate calibration mode.
The console beeps again.

If drive area isn’t clear, press

Down arrow button to

abandon the calibration. This skips to the next item
in the main FUNCTION rotation (speed calibration,
page 51).

Refer to Figure 60

37. Continuing to verify that the drive area is clear, press

the ENGAGE button to start drive rotation.

To terminate calibration mode, press the ENGAGE
or OFF buttons.

Refer to Figure 61

38. While the drive is rotating, the display window shows

the time remaining and the “Out” rate.

The “out=” rate is the estimated area planting rate,
based on motor performance, and is not related to
the sample size. The example screen at right is half-
way through the sample collection, and the actual
motor rate is slightly high.

CONTINUE TO MONITOR DRIVE AREA DURING DRIVE
ROTATION. PRESS THE

ENGAGE BUTTON (OR OFF

KEY) TO STOP DRIVE DURING CALIBRATION

Figure 59

Cal. Mode Clear Area

28258

Figure 60

Cal. Mode Initiate Motion

28259

Figure 61

Cal. Mode Prompt In Motion

28260

Advertising