24

1300 and 1300F

Table of Contents

Index

Great Plains Manufacturing, Inc.

175-157M

Table of Contents

Index

2014-04-15

Refer to Figure 16
6.

Check that the seed/fertilizer flap is closed so seed
and fertilizer cannot pass between compartments.

Flap flips forward to block passage. The flap top
edge is secured to the dividers. Rotate the bent clips
to engage the edge of the flap, and tighten the
knobs.

Refer to Figure 17
7.

Check that fertilizer clean-out door is latched
securely

as shown. Close all door latches before

loading fertilizer compartment.

Refer to Figure 18
8.

Open main seed box lid.

9.

Raise spill flap over fertilizer compartment and swing
it forward until it rests against open drill box lid. The
spill flap serves as a spill guard to keep fertilizer out
of the seed compartment.

10. Fill fertilizer compartment.

11. Calibrate fertilizer application rate as explained in the

Seed Rate manual.

Figure 16

Seed/Fertilizer Flap Closed

16383

Figure 17

Clean-out Door Latch

16377

1

1

Figure 18

Spill Flap Open to Fertilizer

14875