Opener lock up, Point row operation, Fertilizer box operation – Great Plains 2S-2600F Operator Manual v2 User Manual

Page 22

Advertising
background image

20

Section 2 Operating Instructions

2S-2600 and 2S-2600F Two-Section Folding Drill 195-200M-A

9/26/13

Great Plains Mfg., Inc.

Opener Lock Up

Openers must be locked up for transport and drill mainte-
nance. To lock up openers, position opener-transport-lock
handles on both drill sections in road position, then raise
openers completely. See .

To unlock openers, position opener-transport-lock han-
dles in field position, then raise openers completely.

NOTE: Opener-transport-lock handles can be moved with
openers up or down, but transport locks will only engage
after openers are raised completely and disengage after
openers are lowered completely.

Figure 2-12

Opener Lock Up

Point Row Operation

The point-row option allows you to raise and lower open-
ers on one drill section independent of the others. To raise
and lower openers on both sections together, flip power
switch (1) so master-lift-control light (2) is on. Raise or low-
er all openers by moving the switch under the light.

To raise and lower openers on one section independent of
the other, flip power switch so section-control-light (3) is lit.
Raise and lower openers on a section by moving the
switches under the light.

Figure 2-13

Point-Row Control Monitor

NOTE: Turn point row power switch off when tractor is off.

15549

17060

Fertilizer Box Operation

The 2S-2600F is equipped with a fertilizer compartment
so you can plant seed and apply fertilizer in the same field
pass. Use only dry, granular fertilizer in the fertilizer box.

1.

Clean any seed or debris from fertilizer compartment.

2.

Adjust seed and fertilizer compartments to desired ca-
pacity. The 2S-2600F is equipped with standard divid-
ers that partition drill boxes into 60 percent seed and
40 percent fertilizer. If your drill is outfitted with option-
al offset dividers, you can change the seed-to-fertilizer
ratio. Refer to Seed and Fertilizer Capacity, “Adjust-
ments
,” on page 41.

3.

Calibrate fertilizer-application rate as explained under
Fertilizer Rate Calibration, “Adjustments,” page 29.

4.

Check that divider door is closed so seed and fertilizer
cannot pass between compartments. See Figure 2-
16.

5.

Check that fertilizer cleanout door is latched securely
(1) as shown in Figure 2-14. Close all door latches be-
fore loading fertilizer compartment.

Figure 2-14

Cleanout Door Latched

6.

Open lid over fertilizer compartment and swivel back
until it rests against open drill-box lid. See Figure 2-15.
The fertilizer lid serves as a spill guard to keep fertiliz-
er out of the seed compartment.

Figure 2-15

Spill Lid

7.

Fill fertilizer compartment.

16377

1

16375

Advertising
This manual is related to the following products: