33

2014-03-26

Table of Contents

Index

160-219M-A

Fan speed is monitored and reported by the seed
monitor, but is manually controlled. The optimum rate
depends on the seed type and treatments. See “Fan
Speed Adjustment
” in the cart Operator’s Manual for
further information.

Material Rate Risk:
The proper reading for the magnehelic air pressure gauge is
12 to 25 inches of water. A sudden drop in pressure is a sign of
a possible leak which can adversely affect seeding.

Marker Operation

Great Plains does not manufacture markers for this
model drill. If you purchased markers, the marker
manufacturer has supplied operating instructions.
Carefully read marker manufacturer’s instructions for
safe installation, operation and adjustment. You may also
need the following additional information.

Any markers are on a separate hydraulic circuit on the
drill. The leading air cart has provisions for this circuit,
but also shares the circuit for a cart function.

Refer to Figure 39

Markers use hydraulic receptacles

and

on the air

cart.

This cart circuit is shared with the cart seed auger. On a
cart with a hydraulic fan, a manual diverter valve
switches the circuit between markers

and seed

auger

.

This valve is located at the front right corner of the front
bulk hopper. The valve handle must be set to the back
for the markers to function.

If markers are installed, the wing fold Marker Stop fittings
must be [re]installed. See “No-Marker Height
Adjustment
” on page 28.

Figure 38

Fan Air Pressure

26425

Figure 39

Cart Hydraulic Receptacles

26332

Figure 40

Cart Selector for Markers

26417

1