Uneven depth across
drill

Drill not level

See “Level Frame Side to Side” on page 19.
Lift cylinders may also need bleeding. See
Bleeding Lift Hydraulics” on page 17.

Cylinders out of phase

Re-phase cylinders

Weight transfer inoperative

Check valve handle, monitor soft key and gauge
reading

Tire pressures not equal

Check and inflate

Weight transfer to wings too high
or too low.

See “Weight Transfer” on page 42.

Weight circuit flow reversal

Check lever position and hookup. Recheck fan
rotation on any changes.

Press wheel heights not all the
same

Set T-handles the same.

Drill height changing or
creeping

Air in system

See “Bleeding Lift Hydraulics” on page 17.

Worn lift components.

If a cylinder is leaking oil past a seal, consult the
Parts Manual and replace the seal.

Tractor hydraulic malfunction

Confirm by using a different circuit for lift.

Seeding pattern
skipping rows

Plugged openers

Check that disks turn freely. Check scrapers.

Seed hose plugged

Stop and raise drill with fan running. Hand-crank
meter and check for rows not delivering seed.

Hose disconnected or leaking

Check hose path from front cart meter to row unit.
Check for leaks in hoses.

Seed tube plugged

Check for debris and pest nests in tube.

Primary seed hoses are
plugging

Fan speed too low

Increase hydraulic flow to circuit.

Erratic fan speed

Observe rpm reported by monitor, then check for oil
flow surging by tractor.

Flow not stopping when raised

Have observer verify that meter gear rotation
ceases when drill is moving while raised.

Damaged hoses

Inspect and repair as needed.

Sharp bends or too much slack in
hoses

Re-route hoses for minimum necessary slack and
no sharp bends.

Secondary seed hoses
plugging

Fan speed too low

Increase hydraulic flow to circuit.

Damaged hoses

Inspect and repair as needed.

Debris in seed or hoses

Disconnect, inspect and clear.

Sharp bends or too much slack in
hoses

Re-route hoses for minimum necessary slack and
no sharp bends.

Openers plugging

Disks need adjustment

See “Disk Blade Adjustments” on page 45.

Scrapers need adjustment

See “Disk Scraper Adjustments” on page 46.

Conditions too damp

Wait for drier weather.