Veris Drive Operating Instructions

Operating Instructions

Drive Operational Requirements:

Hydraulic System:

Maximum Required Flow:

Minimum Hydraulic Pressure:

Maximum Hydraulic Pressure:

Electrical System:

Voltage:

Amperage:

Closed center, pressure compensated or
load sensed systems only

Drive will not operate on open-centered hy-
draulic systems

2250 psi

3000 psi

8.5 gpm

10.75 gpm

15 - 24’

30’

12 volt DC

4 amperes

Do not weld on drill unless electronic components
are removed.

Return hydraulic valve to neutral position before
exiting tractor cab.

Escaping fluid under pressure can have sufficient pressure to penetrate the
skin. Check all hydraulic lines and fittings before applying pressure. Fluid escap-
ing from a very small hole can be almost invisible. Use paper or cardboard, not
body parts, and wear heavy gloves to check for suspected leaks. If injured, seek
medical assistance from a doctor that is familiar with this type of injury. Foreign
fluids in the tissue must be surgically removed within a few hours or gangrene
will result.