Veris Drive Operating Instructions

GPS - Based Seeding

Settings for FarmWorks SiteMate used with Great Plains Precision Population

Controllers - QUICK REFERENCE GUIDE

(Creat a .shp recipe file in FarmWorks Site Pro, SMS 2.0, SSToolbox, or other
software that will create a .shp file, and transfer it to SiteMate.)

SiteMate Settings: (version 8.12)

1.

Select CONFIGURE tab. Select SETTINGS. Select VARIABLE RATE
SETUP. Select NEW. Type in GP PPC. Under CONTROLLER TYPE, select
Rawson from the scroll-down list. Under COMM PORT select the port
number for the serial card or flash jacket port.

2.

Select MAP tab. Enter DEFAULT rate. This will be the rate that SiteMate will
call for if GPS signal is lost or you are outside the map area, GP Controller
will continue applying rate it was set at when signal was interrupted, until
signal is regained, or another rate is set manually. If power to the SiteMate
is interrupted, you will need to restart the recipe to return to VR. In the
CONVERSION window, enter the conversion rate as follows: if your recipe
(.shp file) is written using the entire number as the desired rate, i.e. 30,000
seeds/acre on the recipe means 30,000 seeds/acre is the desired rate,
enter both the Map Unit and Controller Unit as 1. If the recipe is written
using a different number, i.e. 30 on the recipe means a population of
30,000, then you will need to enter the conversion multiple - in that case 1
Map Unit = 1,000 Controller Units.

3.

Under the APP tab, enter the Feed Delay as 3 seconds. Enter the distance
from the GPS antenna to the Great Plains Mfg, Inc meter. Enter the Swath
Width of the Great Plains unit.

4.

Under the CTRL tab, enter the Nominal Rate as follows: Divide the highest
rate on your recipe by 1.6. This is your Nominal rate. For example, if your
highest rate is 200,000 the nominal is 125,000. If your highest rate is 32,
your nominal rate is 20. Enter the Step as 4%. Exit VRA Controller Setup by
clicking OK button to save the settings.

5.

Under FILE, Open VRT and select the Rx Map (recipe) for the field. Press
the SETUP button and select the GP PPC controller option that you have
set up using these Settings instructions.

6.

Press GO. The Rx rate window shows the rate that is being sent to the GP
Precision Population Controller. The APPLIED window shows the rate that
the GP Controller is applying.