Veris Drive Operating Instructions

1.

Population Monitor rate does not match GP Controller Console

Make certain that SiteMate and GP Controller Console agree. If not, see Troubleshooting

Step 4 above.

Re-check GP calibration number with metering wheel and row spacing.

Re-check planter monitor settings: calibration number, row spacing, number of rows, swath

width, seed, etc.

On small seeds and/or high rates, if population monitor consistently indicated a lower popu-

lation than the GP Controller Console, contact monitor manufacturer for performance specs
for that application.

2.

GPS signal is not being received by SiteMate

Verify that GPS serial port (which is also the docking port) is not set to PC connection only

(Start/Settings/Communications/PC Connections).

Check GPS settings in Configure/Settings/GPS settings/COM (typically COM 1, 4800 Baud,

8 data bits, Parity None, and Stop Bits 1).

Click Data tab to view GPS details.