Operator’s manual, Pto configuration – Great Plains DICKEY-john AI100 10-inch Virtual Terminal User Manual

Page 29

Advertising
background image

OPERATOR’S MANUAL

10" Virtual Terminal

11001-1440-200701

TRACTOR ECU / 27

PTO CONFIGURATION

The PTO Configuration screen determines:

• PTO Working Speed
• PTO High Speed Alarm
• PTO Low Speed Alarm

To configure the PTO:

1. Enter the PPR (pulses per revolution) or number of teeth on the sensor

gear in the PPR input box.

PTO SETUP

1. Enter the value at which the PTO is considered operating in Work

mode.

2. Enter high and low speed alarm limits. If the PTO speed exceeds the

specified maximum, a full alarm screen will display. If the PTO speed is
below the specified minimum, an audio indicator will sound and the
PTO low speed will display on the TECU Work screen.

NOTE: Any values set at 0 will disable

alarms.

Figure 20
PTO Configuration Screen

All necessary precautions must be taken to ensure user safety
around moving parts. Failure to practice all necessary caution may
result in serious injury or death. Refer to the manufacturer’s
operator manual for safety warnings when operating a PTO.

Pulses

Per

Revolution

PTO Configuration button

Work Mode

Advertising