Mount Selector Valve

Refer to Figure 14 (shown without fittings)
38. Examine the valve mount plate

on the top of the

tongue near the hitch. If the plate is unused, continue
at step 39.

If one or two valves are already mounted at the plate
(or installation of one or more two-outlet kits is
pending), mounting the marker selector valve will
require a set of separately-provisioned Grade 5

3

8

-16 hex head cap screws, of suitable length.

39. Select one new:

810-274C DOUBLE SELECTOR VALVE 3/4FORB

and two sets new:

802-168C HHCS 3/8-16X3 1/4 GR5

804-013C WASHER LOCK SPRING 3/8 PLT

803-014C NUT HEX 3/8-16 PLT

40. With the MJIC ends of the elbows pointing forward,

attach the selector valve to the mount plate present
on the forward end of the tongue.

Note: If other valves are present, or to be installed on

this plate, they all need to be stacked using
separately provisioned hardware.

41. Set the selector valve

to Markers (handle at front

stops). This minimizes oil seepage when the existing
fold hoses are connected at step 51.

Install Sequence Valve

Configure Sequence Valve

Refer to Figure 15
42. Select one new:

810-422C VALVE,SEQ SHOEMAKER HI FLO

and four new:

811-169C EL 9/16MJIC 9/16FJIC

On the side of the valve

with four MJIC ports,

attach the elbows

facing outward (toward the

ends of the valves with the adjustment bolts

).

U

D

F

B

L

R

183

149

157

165

5

Figure 14

Selector Valve on Tongue

18937

5

183

149

165

157

183

184

L

R

F

B

D

U

188

6

Figure 15

Sequence Valve Fittings

34783

184

188

184

188

6