Fertilizer meter calibration, Density adjustment – Great Plains 1625AHL Material Rate User Manual

Page 82

Advertising
background image

78

1625AHD/AHL

Table of Contents

Great Plains Manufacturing, Inc.

411-020B

Table of Contents

2014-03-17

Fertilizer Meter Calibration

The rate charts are based on 11-52-0 dry fertilizer with a
density of 0.96 kg/liter (60 pounds per cubic foot).

Material of a different density will meter at a
proportionately different rate. Heavier material has a
higher rate for the same setting. Lighter has a lower rate
for the same setting.

Material with a different particle shape or cohesion may
meter at a slightly different rate, even if the density
matches the charts.

Great Plains strongly recommends calibrating for the
exact material you intend to apply. Adjusting first for
density may allow the calibration to arrive at your desired
rate with fewer samples.

Density Adjustment
If your material density differs from the chart value by
more than a few percent, pick a different initial chart rate,
on an inverse proportion basis:

Figure 20

Gearbox and Calibration Crank

34498

1

3

2

Example Density Adjustment:

Desired

FieldRate

: 104 kg/ha

Default chart gearbox setting: 43

Material

ChartDensity

: 0.96 kg/l

Actual material

FieldDensity

: 1.2 kg/l

Density ratio: 0.80 = 0.96

÷ 1.2

AdjustedRate

: 83.2 = 104

× 0.80

Start with the settings for a rate of 83.2.

Nearest chart rate is: 85.2

Adjusted initial gearbox setting: 39

AdjustedRate

FieldRate

ChartDensity

FieldDensity

-------------------------------

Ч

=

Advertising