0 setpoint configuration displays, 0 specifications – Cooper Instruments & Systems DFI Infinity CS Economy Digital Indicator User Manual

Page 31

Advertising
background image

DFI INFINITY CS (V- M3598/N/0906)

28

CF 70

Table 6-2 Run Mode Displays

Display

X/TARE

S/NT/GRS RESET Description

/

Displays NET or GROSS
reading. Once reading shows,
respective value shows.

Peak Reading


Toggle between Net and Gross
values.

Press to
activate

Will reset your
tare when
viewing this
function

Tare Reset

Reset Latched Alarms

Pressing the RESET button
resets your latched alarm


7.0 SETPOINT CONFIGURATION DISPLAYS

Table 7-1 Setpoint Configuration Displays

MENU

X/TARE

S/NT/GRS Description

Press to scroll to the
next digit to the right

Press to change the
value of the flashing
digit

SETPOINT 1

Select from –1999 through 9999

Press to scroll to the
next digit to the right

Press to change the
value of the flashing
digit

SETPOINT 2

Select from –1999 through 9999


8.0 SPECIFICATIONS

SIGNAL INPUT

Input Ranges:

0-100mV, ± 50 mV, 0-10 V, ± 5 V, 0-20 mA, 4-20 mA

Isolation:

Dielectric strength to 2500V transient per 3mm spacing based on EN 61010 for
260Vrms of DC working Voltage

Noise Rejection:

Normal Mode Rejection (NMR) = 60dB

Common

Mode

Rejection

(CMR)

=

120dB

Resistance:

100 Meg ohms for 100 mV or ±50 mV input range

1 Meg ohm for 10 or +5 V input range

5 ohms for 20 mA current input range

Big Display

:

4-digit, three color programmable 9-segment, LED 21 mm (0.83”)

Symbol:

(-1.9.9.9 ~ 9.9.9.9)

Standard Display:

4-digit, 14-segment LED, 13.8 mm (0.54”)

Symbol:

(-1.9.9.9 ~ 9.9.9.9.)

ANALOG TO DIGITAL

Technique:

Dual

slope

Internal resolution:

15 bits

Read Rate:

3/sec Polarity Automatic

Advertising