Horizontal right--side vent – Carrier DIRECT VENT 4 58HDV User Manual

Page 26

Advertising
background image

26

OF

F

ON

AIR FLOW

Coupling & Clamps
(Optional)

25--24--70c

Single Pressure Switch Detail

Dual Pressure Switch

Tee Trap
White PVC
(loose parts bag)

Flexible Tubing Connector

3

/

16

(4.8mm) OD (Loose Parts Bag)

Barbed Coupling

1

/

2

(12.7mm)

OD (Loose Parts Bag)

EXHAUS

T

Alternate Orientation

Field
Supplied Tee

Cut Here

Drain Tube Black,

5

/

8

(15.9mm) ID & Clamps

Corrugated Cut at straight section

Leave room for clamp

Relief Tube Extension
Black Rubber

3

/

16

(4.8mm) ID

Cut to Fit (Loose Parts Bag)

Plastic Cap
Yellow or black

Vent Drain
& Clamps

Level or Sloped
towards Tee

INLET

On Some Models
ONLY

Elbow Tube Black Rubber

1

/

2

(12.7mm) ID & Clamps

(Loose Parts Bag)

Relief Tube
Black Rubber

3

/

16

(4.8mm) ID

Drain Tube
Black Rubber

1

/

2

(12.7mm) ID

& Clamps

Representative drawing only, some models may vary in appearance.

Remove KO before
mounting Trap

A07712

Fig. 19 -- Horizontal Right Side Vent

Horizontal Right--Side Vent

(See Fig. 19)

Disconnect drain tee if installed
Disconnect the hoses from the trap assembly, and remove trap and

trap mounting bracket from the blower compartment. Using cover
plate and gasket provided in the loose parts bag, cover the hole

from the burner compartment to the blower compartment and

secure with screws.
Remove knockout from the side of the furnace casing where drain

tube will exit.
Mount the trap externally to the bottom side of the unit using the

two(2) screws provided in the location shown.
Cut the corrugated tube as shown in the illustration above. Connect
the corrugated hose from the transition to the trap. Secure

connections with clamps.
Connect the black

1

/

2

″ (12.7mm) ID drain tube from the Vent Drain

to the trap. If an extension is required, use the

1

/

2

″ (12.7mm) OD

barbed coupling and the black

1

/

2

″ (12.7mm) ID drain tube in the

loose parts bag. Cut tube to length. Secure connections with

clamps.
Connect the

3

/

16

″ (4.8mm) ID relief tube to the middle port on the

trap. If an extension is required, use the clear

3

/

16

″ (4.8mm) OD

splice connector and the black

3

/

16

″ (4.8mm) ID relief tube in the

loose parts bag. Cut tube to length.

Cut an appropriate length of 2″ (50.8mm) PVC pipe, fittings and

extension pipe long enough to exit the cabinet and connect the vent

drain to either:

S

A 2″ (50.8mm) PVC coupling fastened onto the drain tee

Install tee trap into bottom section of tee and glue pipe.
Important: The pipe to the tee trap must be level or sloping towards

the tee trap
Connect the tee trap and the main drain line exiting the casing as

shown in Fig. 19.
NOTE:

It is recommended that all PVC piping and fitting

connections be fit up and inspected before final cementing. Both
the external trap and the external tee trap must be primed
before operation.
Verify all condensate drain connections are
securely clamped. A coupling and clamps (in loose part bag) may
be installed as shown for future servicing of the vent system.

58H

D

V