Chapter 9: Troubleshooting

206

HSIM-W6 User’s Guide

WPIM-DDS Installed in HSIM-W6

The DDS circuit is Out of Service (OOS).

•

Contact your WAN DDS Service Provider and have them test the operation of your DDS circuit.

Status (STS) LED is AMBER (blinking)

•

Device is in test mode.

•

The CSX400 is running its Power-up Diagnostic Tests.

•

Loopback Testing is underway on a WAN circuit.

Status (STS) LED is GREEN

WPIM-SYNC Installed in HSIM-W6

The Port is operating normally; Request to Send (RTS) has been activated by your WAN device. If
it is not, use the following steps:

•

Use QuickSET or Local Management to make sure that the WAN interface on the local device
is configured properly.

•

Verify the cabling being used between the HSIM-W6 and the CSU/DSU.

WPIM-HDSL is Installed in HSIM-W6

The Port is operating normally, the WPIM is synchronized with the HDSL circuit at the remote
end.

WPIM-S/T is Installed in HSIM-W6

The Port is operating normally, ISDN BRI channel B1 or B2 or both are active.