Dutchwest Direct Vent / Natural Vent Gas Heater

30001935

Install the Vent Adapter Pipe

(Simpson Dura-Vent Components)
1. Install the Restrictor Plate.
Consult the ‘Vent Run

Specifications’ on Page 8 to determine whether the
restrictor plate is needed. If so, put the restrictor
plate in place within the inner flue collar. (Fig. 16)

2. Discard the inner starter pipe shipped with the log-

set. Using the starter pipe assembly listed on Page
7, slide the inner section out to allow access.

• Run a bead of sealant around the bottom end of

the starter pipe and attach the assembly to the stove
using three 1/4-20 x 3/8” Phillips screws provided in
the parts bag. (Fig. 20)

3. Install the Outer Adapter Pipe. Apply a 1/4” bead

of cement around the outside surface, about one
inch from the crimped end. (Fig. 21) Orient the verti-
cal seam to the rear, and insert the crimped end of
the outer pipe into the flue collar. Fasten with three
sheet metal screws provided.

ST762

dura vent

attach inner assy

5/15/03 djt

CEMENT

1/4-20 x 3/8

Phillips Screws

Inner Adapter

Pipe

ST762

Fig. 20 Simpson DuraVent - install inner adapter pipe.

ST763

DW dura vent

attach outer assy

5/15/03 djt

ST763

Fig. 21 Simpson DuraVent - install outer adapter pipe.

Side Wall Termination Assembly

1. Locate the vent opening on the wall. Refer to Fig-

ure 5, Page 6, to determine the opening centerline.
It may be necessary to first position the stove and
measure to find the hole location. Depending on
whether the wall is made of combustible materials,
cut the opening to the size shown in Figure 22. Com-
bustible wall openings must be framed as shown in
Figure 22.

VO584-100

Vent Opening

2/99 djt

CFM System

9³⁄₈”

(240 mm

Combustible Wall

Framing Detail

10”

(250 mm)

7¹⁄₂”

(191 mm)

9³⁄₈”

(240 mm

10”

(250 mm)

DuraVent
System

VO584-100

Fig. 22 Locate vent opening.

2. Measure the wall thickness and cut the wall sleeve

sections to proper length (MAXIMUM 12”). Assemble
the sleeve with the #8 sheet metal screws supplied.
Attach the firestop plate to the sleeve end with the
holes. (Fig. 23) NOTE: The wall sleeve is required
in combustible walls only.

3. Install the Wall Firestop/Sleeve assembly into the

wall cutout and fasten the firestop to the wall cutout
framing members. (Fig. 23)

ZCS103

Zero Clearance Sleeve

& Firestop

12/6/99 djt

Sleeve

12”

(305 mm)

Max. Length

Firestop

ZCS103

Fig. 23 Assemble the wall sleeve and firestop.