Dutchwest Direct Vent / Natural Vent Gas Heater

30001935

Pilot Orifice Conversion
1. Locate pilot. (Fig. 49)
2. Replace pilot orifice.
Pilot Type 1
• Remove pilot hood by lifting up. (Fig. 53) Do not

remove snap ring to remove pilot hood. NOTE: It is
not necessary to remove the pilot tube for conver-
sion.

• Remove pilot orifice with allen wrench. (Fig. 54)
• Install the conversion orifice.
• Reinstall pilot hood. Be sure to align hood with

index tab.

Pilot type 2
• Loosen pilot hood turning counterclockwise using a

7/16” wrench. (Fig. 55) NOTE: You may use pen-
etrating oil to prevent pilot hood threads from seizing
up.

FC107

SIT820

valve conversion

10/03

A

B

C

OFF

PIL

OT

O

Fig. 51 Remove mounting screws, pressure regulator tower
and spring and diaphragm assembly.

FC107

D

E

F

FC108

SIT

regulator

conversion

10/03

OFF

PIL

OT

O

FC108

Fig. 52 Replace regulator.

CO105a

gas conversion

Pilot

1/28/00 djt

Pilot Hood

Pilot
Bracket

CO105a

Fig. 53 Remove pilot hood.

CO106a

DV360/580

Gas Conversion

Pilot2

1/28/00 djt

Index Tab

Allen Wrench

Snap Ring

CO106a

Fig. 54 Remove pilot orifice.

• Remove pilot orifice with needlenose pliers. (Fig.

56) NOTE: Use a wrench to hold pilot tube in place
while removing the orifice.

• Install the conversion orifice.
• Reinstall pilot hood and tighten until mark on pilot

hood aligns with mark on pilot bracket.

NOTE: Be sure burner leg remains at a 90° angle to

firebox base after conversion.

CO105

Gas Conversion

Pilot

2/15/99 djt

Pilot

Index

Marks

Pilot Bracket

CO105

Fig. 55 Remove pilot hood. (Your pilot may have a different
appearance).

CO106a

Gas Conversion

Pilot (Vermont)

7/19/99 djt

Pilot Orifice

CO106b

Fig. 56 Remove pilot orifice.