Dutchwest direct vent / natural vent gas heater, Gas specifications, Gas inlet and manifold pressures – Vermont Casting 2466 User Manual

Page 7: Horizontal termination - direct vent only

Advertising
background image

7

Dutchwest Direct Vent / Natural Vent Gas Heater

30001935

Max.

Min.

Input

Input

Model

Fuel

Gas Control

BTU/h BTU/h

2465

Nat

Millivolt

28,000 20,000

2466

Prop

Millivolt

28,000 19,000

Gas Specifications

Weight: Fully assembled; 202 lbs.

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Dutchwest Direct Vent/Natural Vent

Certified to:

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

The installation of your Dutchwest stove must
conform with local codes, or in the absence of lo-
cal codes, with the National Fuel Gas Code ANSI
Z223.1/NFPA 54 - latest edition, or CSA B149.1
Installation code. (EXCEPTION: Do not derate this
appliance for altitude up to 4,500 feet (1,370m).
Maintain the manifold pressure at 3.5” w.c. for
Natural Gas and 10.0” w.c. for LP Gas.

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).

WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause in-
jury or property damage. Refer to this manual for
correct installation and operational procedures.
For assistance or additional information consult
a qualified installer, service agency, or the gas
supplier.

Horizontal Termination -

Direct Vent ONLY

The vent must rise vertically a minimum of 24” (610mm)
off the top of the unit, before the first elbow. The hori-
zontal run may extend up to 20’ (6m) and include a
vertical rise of up to 40’ (12m). (Fig. 7) Horizontal
termination must also meet the criteria shown in Figures
9 through 11.
• Approved vent systems must terminate above and

including the heavy line in Figure 7.

• Two 45˚ elbows may be substituted for each single

90˚ elbow.

• With a rise between 2’ - 5’, one 90˚ or two 45˚ el-

bows may be used.

20
19
18
16
15
14
13
12
11
10
9
8
7
6
5

4
3

2
1
0

1 2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20

Ve

rtical Run (in feet)

(Measured from the appliance flue coll

ar to the top of the v

ent pipe

.)

Horizontal Run (in feet)

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

ST134a

FDV28

Horizontal

vent run

12/3/99 djt

areas modified

1/11/00 djt

ST134a

Fig. 7 Horizontal vent termination window.

May use up to three

90° Elbows

One 90°

Elbow

Unacceptable Venting

Configuration

Advertising