Dutchwest direct vent / natural vent gas heater, Wall centerline from floor, Wall and ceiling clearances – Vermont Casting 2466 User Manual

Page 6: Hearth requirements

Advertising
background image

6

Dutchwest Direct Vent / Natural Vent Gas Heater

30001935

Parallel Installation:

Minimum Clearance and Flue Centerline,

Direct Vent and Natural Vent

ST128b
Stardance
flue centerline
9/28/00 djt

C

L

C

L

B

D

C

A

ST128c

Stove Clearances

A: 4” (102 mm)

B: 4” (102 mm)

Pipe Centerlines

C: 15¹⁄₂” (395 mm)

D: 9” (229 mm)

Fig. 3 Parallel installation, minimum back and side clear-
ances and flue centerlines.

Corner Installation:

Minimum Clearance and Flue Centerline

Direct Vent and Natural Vent

ST129c
Dutchwest
corner specs
5/15/03 djt

A

A

B

B

ST129c

Stove Clearance

A: 4” (102 mm)

Pipe Centerline

B: 14¹⁄₂” (370 mm)

Fig. 4 Corner installation, minimum corner clearances and
flue centerline.

Wall Centerline from Floor

ST131c

Dutchwest

wall thimble

5/15/03 djt

A

A

Effective Minimum
Wall Thimble

57¹⁄₂” (1461 mm) (CFM Pipe)

Centerline

53¹⁄₂” (1359 mm) (Simpson DuraVent Pipe)

ST131c

Fig. 5 Minimum wall thimble centerline.

Wall and Ceiling Clearances

A

C

D

ST101c

Dutchwest

Direct Vent

Min. Clrnc

5/15/03 djt

B

A: Rear Wall

4” (102 mm)

B: Min. Clearance

45¹⁄₂” (1156 mm)*

C: Min. Alcove Height

73¹⁄₂” (1867 mm)*

D: Max. Alcove Depth

48” (1220 mm)

Sidewall Clearance

4” (102 mm)

* needed for installing DuraVent Minimum Vent Kit #2792 or CFM Corpora-
tion Minimum Vent Kit #7TFSDVSK.

ST101c

Fig. 6 Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Dutchwest Heater must be installed on rigid floor-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.

Advertising