21. Replace burner. Slide the burner in at an angle

with left side lower than the right side. Slide the left
side onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.

NOTE: It is very critical to keep the left burner leg,

which holds the injectors, at a 90° angle to the base.
(Fig. 57) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.

22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
26.Replace glass and stove front.
Conversion is complete.

ST353

air shutter adjust

burner replace

3/20/00 djt

90°

Left Burner Leg

Injector Shoulder

ST353

Fig. 57 Be sure to maintain 90° angle at left burner leg.

Conversion to Natural Gas

Input (BTU/h)

Kit #

Front

Part #

Rear

Part #

Minimum

Maximum

000-5021

#54 / .055”

30000514

#44 / .086”

30000334

19,000

28,000

Conversion to LP

Input (BTU/h)

Kit #

Front

Part #

Rear

Part #

Minimum

Maximum

000-5022

#69 / .029”

30000513

#54 / .055”

30000514

20,000

28,000

Table 2. Injector Orifice Size Matrix