Dutchwest direct vent / natural vent gas heater, Thermostat connection (optional), Install the stove front – Vermont Casting 2466 User Manual

Page 22

Advertising
background image

22

Dutchwest Direct Vent / Natural Vent Gas Heater

30001935

Thermostat Connection (optional)

Use only a thermostat rated for 500 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.

Thermostat

Wire / Gauge

Maximum Run

18

20 feet

16

20 - 40 feet

14

up to 60 feet

1. Install the wall thermostat in the desired location and

run the wires to the stove location. Terminate these
leads with 1/4” female connectors.

2. Connect the thermostat wires to the valve. (Fig. 42)

Install the Stove Front

Insert the handle stub into the hole in the front casting.
Fasten in place witht he 3/8” locking nut provided. (Fig.
43)
The front attaches to the stove by four steel tabs that
engage with corresponding cast ribs onto the sides
and bottom of the stove body. Position the front about
3” down from stove top and lift the plate to engage the
upper tabs behind the adjacent ribs on the sides. (Fig.
44) Then lower the front into position, so the lower tabs
engage with the corresponding ribs at the bottom.
When properly installed, the bottom of the stove front
cannot be pulled away from the sides without also lifting
it.

ST773

handle assy

6/6/03

3/8” Locking

Nut

Handle Stub

ST773

Fig. 43 Insert handle stub into hole in front. Secure with 3/8”
locking nut.

D

UTCH

W

EST

D

UTCH

W

EST

Est. 1974

ST771

DW

stove front

5/30/03 djt

Engage steel tabs behind
the cast iron bosses

Bottom tabs engage
notch in the leg

ST771

Fig. 44 Install the front plate.